Objective
To reduce the SMI-S provider workload and therefore improve performance, it is recommended to remove some EMC systems from the SMI-S provider. This action can be performed with the remsys command.
Pre-requisites
The “remsys” command requires SMI-S 4.3.x or later.
Procedure
- Log into the server where the SMI-S Provider is installed.
- Open a command prompt.
- Change directory to: C:\Program Files\EMC\ECIM\ECOM\bin (where C:\ is the ECIM install drive).
- Type TestSmiProvider to launch the utility.
- Login with an Admin username and password.
- Type “ein” to enumerate instance names.
- Type the class value “Symm_StorageSystem”. The utility should       produce an output similar to the following:++++ Testing EnumerationInstanceNames: Symm_StorageSystem ++++ 
 Instance 0:
 Symm_StorageSystem.CreationClassName="Symm_StorageSystem",Name="SYMMETRIX+0001949xxxxx"Instance 1:
 Symm_StorageSystem.CreationClassName="Symm_StorageSystem",Name="SYMMETRIX+0001949xxxxx”
- Copy  the entire path of       the array that you wish to remove  
 Example: Symm_StorageSystem.CreationClassName="Symm_StorageSystem",Name="SYMMETRIX+0001949xxxxx"
- Append the EMC Symmetrix path to WBEM server path. 
 Example: //11.1.11.111/root/emc:Symm_StorageSystem.CreationClassName="Symm_StorageSystem",Name="SYMMETRIX+0001949xxxxx"
- Type “remsys”.
- Type “Y” to confirm.
- Paste the new object path at the Systems ObjectPath prompt.
- Type “Y” to confirm.
The EMC Symmetrix array should now be removed. You can run a “dv” command to verify the system has actually been removed.
Related Topics
- Removing an EMC CLARiiON System from the SMI-S Provider
- Verifying that Every EMC Disk Arrays are Properly Attached to an EMC SMI-S Provider
- Preventing the Automatic Discovery of EMC Symmetrix Arrays
- How to Rebuild the SYMAPI Database in the EMC SMI-S Provider
- How to Monitor Dell EMC VMAX/PowerMax Storage Systems with Storage Analyzer KM